Sample record · Freedom Diagnostics · 2026-11-04
A permanent reference for the submitted Retatrutide 30 mg · lot Q sample. This certificate does not cover the 20 mg variant or any other lot, and does not identify the lot currently shipping.
What the lab reported
- Identity
- Confirmed; analytical result: GLP RT (LC-MS)
- Purity
- 99.95% (HPLC-UV)
- Net content
- 30.93 mg
- Endotoxin
- Pass in both replicates; stated assay sensitivity ≤0.05 EU/mL (LAL, USP <85>)
Transcribed from the original report. Purity, net content and endotoxin are separate measurements. An endotoxin pass is not a sterility result.
Sample & report details
- Lot
- Q
- Submitted sample
- Grey-cap vial; white lyophilized powder
- Accession
- 2611031112
- Lab search code
- Amin2611031112
- Received
- 2026-11-03
- Reported
- 2026-11-04

What this record does not establish
The lab’s findings apply to the sample submitted. They do not independently establish the composition of every vial in a lot, storage history, or the identity of a different shipment.
This report does not include a sterility result, a residual-solvent panel, a heavy-metal panel, or a stability study. Unreported tests are unknown, not passes. The report does not establish safety, efficacy, or suitability for human or veterinary use. These materials are for laboratory research only.
Original file & verification
Compare the accession, lot and sample details with the lab-hosted document. Contact the issuing lab if any detail differs. The copy stored here is byte-for-byte identical to the lab PDF checked on 2026-11-05.
SHA-256: ed59f6353e8165d42e79024535807bf1e5c4b1223bf21c0764f6f9b004f03a7b